Nitric acid production brings with it a need to measure and report emissions to atmosphere to prove compliance with regulations, which unusually comprises two distinct requirements. There is a conventional need to report emissions to air for the sum of oxides of nitrogen (i.e. NO + NO2) and ammonia according to prescribed emission limit values for those species. In addition to this, the unwanted generation of nitrous oxide (N2O) must also be reported. However, for greenhouse gases the regulations differ, in that a mass emission must be reported. These contrasting reporting mechanisms add complexity to the demands placed on the continuous emission monitoring analysis system used as the basis for reporting purposes.
The tail gas composition resulting from nitric acid production is quite unique, so it follows that applying a conventional emission monitoring technology may not be the best fit. Furthermore, in recent years, significant developments in abatement technologies, coupled with the implementation and fiscal relevance of global carbon trading schemes have radically altered not just the tail gas composition, but fundamental expectations on the sensitivity and precision of the N2O mass emission reporting.
Highly effective abatement systems have reduced emissions to air of oxides of nitrogen and nitrous oxide from nitric acid production. These changes have placed additional requirements on continuous emission monitoring systems, with an increase in complexity, seen both in terms of the number of gaseous components to be measured as well as a need to sensitively measure the target gases at increasingly low concentrations with low measurement uncertainty.
A single hot wet extractive multicomponent infra-red analyser is well suited to the task of reporting emissions from nitric acid production, relevant both to monitoring emission limit values of NO, NO2 and NH3, as well as the N2O mass emission, in combination with an ultrasonic flowmeter. The hot extractive analyser technology is flexible enough to be able to include additional measured components, for example to also measure carbon monoxide, carbon dioxide and methane in the event that natural gas is dosed as a reagent as the basis for a tertiary N2O abatement system.
Future requirements for continuous emission monitoring systems will focus on the ability to measure very low concentrations with the best achievable uncertainty for the N2O measurement. The most important consideration to achieve the best possible uncertainty performance in relation to the N2O mass emission, is based around the on-site ‘QAL 2’ calibration. The monitoring systems must also retain the flexibility to measure much higher emission concentrations such as those prevalent during start-up conditions.